App Update

6 New Components in ElectraSim: RCD, Contactor, Timer Switch, Dimmer Switch, Distribution Board & Bell

📅 ✍️ ElectraSim ⏱ 10 min read

ElectraSim’s component library just got a major upgrade. Six new electrical components are now available on the canvas — covering protection, automation, control, and signalling. Whether you’re a student learning circuit design, an electrician practising wiring layouts, or a hobbyist building virtual panels, these additions let you model significantly more realistic electrical systems.

Here’s a complete guide to each new component, what it does in the real world, and how to use it in ElectraSim.

Try all of them now in ElectraSim →


1. RCD / RCCB — Residual Current Device

Category: Protection

An RCD (Residual Current Device) — also called an RCCB (Residual Current Circuit Breaker) — is one of the most important safety devices in modern electrical installations. It detects leakage current: a tiny imbalance between the current flowing out on the Live wire and returning on the Neutral wire. Even a few milliamps of leakage can indicate that current is taking an unintended path — through a person, for example.

How it works: The RCD continuously compares current on Live and Neutral. Under normal conditions they’re equal. If Live current exceeds Neutral current by as little as 30mA (the standard trip threshold for personal protection), the RCD trips in under 40 milliseconds — fast enough to prevent lethal electrocution.

Where RCDs are used:

In ElectraSim: The RCD has four ports — Live-in, Neutral-in, Live-out, and Neutral-out. Wire it in series between the supply and the loads it protects. It monitors both the Live and Neutral paths simultaneously.

Live (L) → RCD (L-in → L-out) → Load
Neutral (N) → RCD (N-in → N-out) → Load

💡 Key difference from MCB: An MCB protects against overload and short circuit. An RCD protects against earth faults and electrocution risk. In modern installations they’re often combined into a single device called an RCBO. In ElectraSim you can model this by using both an MCB and an RCD in series.


2. Contactor — High-Power Electrically-Controlled Switch

Category: Switch / Control

A contactor is an electrically operated switch designed for switching high-power loads — motors, HVAC compressors, industrial machinery, and large lighting banks. Unlike a standard light switch (which you operate manually), a contactor is controlled by a separate low-voltage coil circuit. When the coil is energised, it closes the main contacts, allowing high current to flow through the load circuit.

Why use a contactor instead of a switch? A standard switch is designed for the current it directly carries. A contactor separates the control circuit (low current, safe to touch) from the power circuit (potentially hundreds of amps). This allows remote control, automated switching via timers or sensors, and safe operation of loads that would destroy a standard switch.

Typical applications:

In ElectraSim: The Contactor has four ports — Live-in/out and Neutral-in/out. Wire it in the same way as an RCD. It behaves as a manually toggled switch in the simulator (representing coil energised / de-energised). Use it to model any circuit where you need a high-power switching point that’s separate from the control logic.

💡 Circuit idea: Wire a Push Button to represent the coil control circuit, and a Contactor to switch a Motor. This models a basic motor starter — press the button to start, press again to stop.


3. Timer Switch — Automatic Time-Based Control

Category: Timer / Automation

A timer switch automatically opens or closes the circuit at pre-programmed times — no human intervention needed once it’s set. It’s one of the simplest forms of electrical automation and is used everywhere from staircase lighting to garden irrigation.

Types of timer switches in real installations:

Typical uses:

In ElectraSim: The Timer Switch has two ports — Live-in and Live-out — and behaves like a single-way switch that you can toggle to represent the timer triggering. Wire it in series before the loads it controls. Use it with a Bulb or Socket to model timed lighting circuits.

💡 Circuit idea: Wire a Timer Switch in series with an outdoor Bulb. Toggle the switch to simulate the timer reaching its ON time. Add an MCB upstream for a realistic outdoor lighting circuit.


4. Dimmer Switch — Variable Brightness Control

Category: Control

A dimmer switch reduces the voltage delivered to a lighting load, allowing you to adjust brightness from 0–100%. Modern dimmers use phase-cut technology (either leading-edge or trailing-edge) to rapidly switch the AC cycle on and off, effectively reducing the average power delivered to the bulb.

Leading-edge vs trailing-edge:

Always match the dimmer type to your bulb type — using a leading-edge dimmer with LED lamps causes flickering, buzzing, and reduced lifespan.

Typical uses:

In ElectraSim: The Dimmer Switch has two ports — Live-in and Live-out — and connects in series between the MCB and the Bulb. The simulator models it as a controlled pass-through: it can be toggled to represent full-on vs dimmed state. Wire it the same way as a single-way switch, but note it is for lighting loads only — connecting a Dimmer to a motor or fan is incorrect wiring (use the Fan Dimmer component for fans instead).

💡 Note: ElectraSim also has a Fan Dimmer component, which is the rotary speed controller used specifically with ceiling fans. The Dimmer Switch is specifically for lighting circuits.


5. Distribution Board — Consumer Unit / Fuse Box

Category: Protection / Distribution

The Distribution Board (also called a consumer unit, fuse box, or breaker panel) is the central hub of any electrical installation. It takes a single incoming supply and distributes it to multiple independent circuits, each protected by its own MCB.

What’s inside a real distribution board:

In ElectraSim: The Distribution Board has seven ports:

Connect an MCB to each Live output to model individual circuit protection. This lets you build a complete representation of a home’s electrical panel.

Example panel layout:

Live (L) → Distribution Board (L-in)
Neutral (N) → Distribution Board (N-in)

L1 → MCB1 → Lighting circuit
L2 → MCB2 → Ring main (sockets)
L3 → MCB3 → Kitchen circuit

N1 → Neutral return for lighting + ring main
N2 → Neutral return for kitchen

💡 Circuit challenge: Build a three-circuit panel: one for lighting (Bulb + Switch), one for sockets (3-Pin Socket), and one for a motor. Wire all three through the Distribution Board and add individual MCBs on each output.


6. Bell / Buzzer — Signalling Load

Category: Load

The Bell / Buzzer component represents an electromechanical bell (ding-dong style), a continuous buzzer, or any electronic sounder used for signalling or alerting. It is a load — it consumes power to make sound. Unlike a switch or protection device, it does not control or protect the circuit; it simply responds to being energised.

Types of real-world signalling devices this represents:

In ElectraSim: The Bell / Buzzer has two ports — Live and Neutral — wired exactly like a Bulb. It is treated as a load and activates when both Live and Neutral are connected and the simulation is running.

Classic doorbell circuit:

Live (L) → Push Button → Bell → Neutral (N)

The Push Button is momentary (closes only while held), so the Bell sounds only while the button is pressed — exactly how a real doorbell works. This is one of the simplest and most satisfying circuits to build in ElectraSim.

💡 Circuit idea: Build a doorbell with two buttons — one at the front door and one at the back — wired in parallel, both feeding the same Bell. Either button triggers the bell independently.


Putting It All Together — A Complete Modern Panel Circuit

With all six new components available, here’s a realistic full-installation layout you can build in ElectraSim:

Live (L) → Distribution Board
Neutral (N) → Distribution Board

DB L1 → RCD → MCB → Lighting circuit (Switch + Bulb)
DB L2 → MCB → Timer Switch → Outdoor Bulb (automated lighting)
DB L3 → MCB → Dimmer Switch → Ceiling Bulb (dimmable mood lighting)
DB L4 (future) → Contactor → Motor (pump or HVAC)
DB L5 (future) → MCB → 3-Pin Socket → Bell (doorbell circuit via Push Button)

This gives you:

Build this in ElectraSim →


Component Summary

ComponentCategoryKey Use
RCD / RCCBProtectionEarth fault + electrocution protection
ContactorSwitchHigh-power load switching via coil
Timer SwitchAutomationScheduled on/off without manual intervention
Dimmer SwitchControlVariable brightness for lighting loads
Distribution BoardDistributionDistribute supply to multiple circuits
Bell / BuzzerLoadDoorbell, alarm, and signalling circuits

Key Takeaways

All six components are available now — free, no sign-up needed.

Open ElectraSim and start building →

See It All in Action

Build and simulate the circuits from this article for free in your browser. No installation, no sign-up.

⚡ Open ElectraSim Free